Uses
Dosage & preparation
Highlighted claims
- During two-lung ventilation, tidal volume is 6–8 mL/kg based on ideal body weight. — Laryngeal mask airway combined with visual bronchial blocker versus double-lumen tube for lung isolation in video-assisted thoracoscopic surgery: a protocol for a multicentre randomised controlled trial
- During one-lung ventilation, tidal volume is 4–6 mL/kg with a respiratory rate of 10–16 breaths/min. — Laryngeal mask airway combined with visual bronchial blocker versus double-lumen tube for lung isolation in video-assisted thoracoscopic surgery: a protocol for a multicentre randomised controlled trial
- PEEP is set at 4–6 cmH₂O for all patients except those with COPD. — Laryngeal mask airway combined with visual bronchial blocker versus double-lumen tube for lung isolation in video-assisted thoracoscopic surgery: a protocol for a multicentre randomised controlled trial
- End-tidal CO₂ is maintained at 35–45 mmHg throughout ventilation. — Laryngeal mask airway combined with visual bronchial blocker versus double-lumen tube for lung isolation in video-assisted thoracoscopic surgery: a protocol for a multicentre randomised controlled trial
- If significant air leak occurs with applied PEEP, the level is titrated downward to maintain SpO₂ ≥94%. — Laryngeal mask airway combined with visual bronchial blocker versus double-lumen tube for lung isolation in video-assisted thoracoscopic surgery: a protocol for a multicentre randomised controlled trial