Prefilled RCA-CVVH
Cross-source consensus on Prefilled RCA-CVVH from 1 sources and 5 claims.
1 sources · 5 claims
Dosage & preparation
Preparation
Highlighted claims
- Initial prefilled CVVH settings include blood flow of 150 mL/min, citrate replacement fluid at 1500 mL/hour, and calcium-containing replacement solution at 500 mL/hour. — Prefilled versus infused regional citrate anticoagulation during continuous renal replacement therapy on circuit lifespan: protocol for a randomised controlled trial
- The prefilled group receives sodium citrate haemofiltration replacement fluid as the predilution solution. — Prefilled versus infused regional citrate anticoagulation during continuous renal replacement therapy on circuit lifespan: protocol for a randomised controlled trial
- The prefilled protocol uses calcium-containing replacement solution for postdilution. — Prefilled versus infused regional citrate anticoagulation during continuous renal replacement therapy on circuit lifespan: protocol for a randomised controlled trial
- Prefilled RCA-CVVH adjustments target post-filter ionised calcium of 0.25-0.35 mmol/L. — Prefilled versus infused regional citrate anticoagulation during continuous renal replacement therapy on circuit lifespan: protocol for a randomised controlled trial
- The postdilution rate is adjusted to maintain total effluent dose and keep filtration fraction below 25%. — Prefilled versus infused regional citrate anticoagulation during continuous renal replacement therapy on circuit lifespan: protocol for a randomised controlled trial